Drive rod installation: A drive rod helps seat the anchor in place, ensuring a snug fit.Unique shape: The arrowhead shape digs deep, providing a stronghold in various soil types.Here’s the lowdown on their holding strength and key features: Installed with a drive rod, they’re like the Swiss army knife of anchors. Resistance to pullout: The design ensures that the anchor stays put when it’s most needed.Īrrowhead anchors are another popular option, especially when it comes to soils that play hard-to-get.Solid construction: These anchors are built tough to withstand mother nature’s whims.Threaded shaft: The secret sauce is in the threaded shaft, which screws easily into the ground.They’re installed with the help of a trusty impact wrench, making quick work of the job.īut what makes these anchors the bee’s knees in holding strength? Let’s take a gander: Penetrator anchors are the darlings of the clay and sandy soil world. Power Pole Anchor Types Penetrator Anchors Going the Extra Mile: Advanced Anchoring Techniques.The Art of Measurement: A Hole New World.How Far in the Ground is a Telephone Pole?.The Anchor’s Role in the Bigger Picture.
#Utility pole guy wire installation how to
I Spy with My Little Eye: How to Spot an Anchored Telephone Pole. Arrowhead and Bullet Anchor Maintenance. Arrowhead and Bullet Anchor Installation. So strap in and join me on this thrilling journey as we dive into the fascinating world of electric pole anchoring. There are various types of anchors used to secure these beauties, such as Penetrator, Arrowhead, and Bullet anchors.Ī pole doesn’t just sit on the ground (in most cases) instead pole anchors in the ground are used to keep the utility pole in place and make sure it doesn’t start leaning or fall over entirely. The choice of anchor depends on the soil type and holding strength required.Īnchors are the unsung heroes that hold these poles in the ground. These anchors, along with anchor rods, provide stability and ensure the pole remains upright and secure. Yes, a telephone pole is anchored into the ground using various types of anchors, such as Penetrator, Arrowhead, and Bullet anchors. If the guy cable is steeper than 45 degress you should probably use a longer cable insteadĪfter writing the above I found this picture in the Nichols catalog (linked from the page you linked) it seems to cover all the points I made above.Ah, the humble telephone pole! A marvel of modern engineering, these soaring giants connect us to the world through a dizzying network of wires.īut what keeps them standing tall and proud? Anchors, my friends! Running the guy cable flat is allowable, sloping down to the roof is normal, sloping the other way is probably not a good idea, as the cable would then carry extra rain water to the pole. that are the correct distance from the pole. That kit comes with fixed length 6' cables with only a little adjustment in the bracket so you need to find hardpoints on the roof (like a rafter or purlin) that you can bolt through. Is there a distance away from mast or angle down I should aim for when determining where the roof attachments go? (eg 30 to 45 degrees off directly behind the feed, but you'll be constrained by what is available to bolt to) In the the opposite direction that the supply cable is coming from, but slightly to the side. What directions should the wires head away from the mast? How high up should the wires be attached to the mast?Īs high as is practical, the higher it is the less lever effcet is multiplying the tension in feed wire. But, I should probably add the guy wires that make sense now, and worry about the future when it happens. They may even go underground (in which case, at some point, this all becomes moot). #Utility pole guy wire installation upgrade
PoCo wants to upgrade service wires in the neighborhood. With that said, though, I hesitate to add guy wires based on that. The power pole is currently about 15' beyond the right end of the house and about 10' in front of the front of the roof line. If it'll help, I can get a better shot next time I'm on site (if the rain lets me).
E.g., how high up should the wires be attached to the mast? What directions should the wires head away from the mast? Is there a distance away from mast or angle down I should aim for when determining where the roof attachments go?
#Utility pole guy wire installation install
I'm wondering if someone can provide guidance on how to install it. It's probably 3-3 1/2') and is a 3" mast and will have heavy wires attached, it needs a guy wire (or wires?).
Inspector said since the mast is more than 2' above the roof (I wanted separation between service wires and metal roof. One of them was "add guy kit on service mast".
I recently had my first inspection after upgrading meter box from 200A service to 400A service.